PERFORMANCE ANALYSIS OF A NEW LP STAGE LOCATED UPSTREAM THE EXTRACTION POINT IN A 225 MW TURBINE

  • Andrzej Gardzilewicz
  • Mariusz Szymaniak
  • Jerzy Głuch

Abstract

A new design of steam turbine stages upstream an extraction point is presented. In this solution a special ring guides the steam leakage flow directly to the heat exchanger. The experiments and calculations have confirmed advantages of the new design as manifested by turbine operating features and efficiency. The design has been applied in 30 old turbines with Baumann stages. Recently, the patent was used in the LP exit ND-41A of modernised 225 MW turbines in the Polaniec and Kozienice power plants.
Published
2012-12-20
How to Cite
GARDZILEWICZ, Andrzej; SZYMANIAK, Mariusz; GŁUCH, Jerzy. PERFORMANCE ANALYSIS OF A NEW LP STAGE LOCATED UPSTREAM THE EXTRACTION POINT IN A 225 MW TURBINE. Journal of Power Technologies, [S.l.], v. 92, n. 4, p. 241--248, dec. 2012. ISSN 2083-4195. Available at: <https://papers.itc.pw.edu.pl/index.php/JPT/article/view/298>. Date accessed: 19 apr. 2024.
Section
Power Plant

Most read articles by the same author(s)

Obs.: This plugin requires at least one statistics/report plugin to be enabled. If your statistics plugins provide more than one metric then please also select a main metric on the admin's site settings page and/or on the journal manager's settings pages.