PERFORMANCE ANALYSIS OF A NEW LP STAGE LOCATED UPSTREAM THE EXTRACTION POINT IN A 225 MW TURBINE
Abstract
A new design of steam turbine stages upstream an extraction point is presented. In this solution a special ring guides the steam leakage flow directly to the heat exchanger. The experiments and calculations have confirmed advantages of the new design as manifested by turbine operating features and efficiency. The design has been applied in 30 old turbines with Baumann stages. Recently, the patent was used in the LP exit ND-41A of modernised 225 MW turbines in the Polaniec and Kozienice power plants.
Published
2012-12-20
How to Cite
GARDZILEWICZ, Andrzej; SZYMANIAK, Mariusz; GŁUCH, Jerzy.
PERFORMANCE ANALYSIS OF A NEW LP STAGE LOCATED UPSTREAM THE EXTRACTION POINT IN A 225 MW TURBINE.
Journal of Power Technologies, [S.l.], v. 92, n. 4, p. 241--248, dec. 2012.
ISSN 2083-4195.
Available at: <https://papers.itc.pw.edu.pl/index.php/JPT/article/view/298>. Date accessed: 22 dec. 2024.
Issue
Section
Power Plant
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).